 Post subject: diesel hp VS electric hp
PostPosted: Mon Sep 29, 2008 4:41 am 
Offline

Joined: Mon Sep 29, 2008 4:18 am
Posts: 1
Hi,
I would like to know if,when replacing a diesel engine with an electric motor someone need to look for the same HP for the electric motor as the hp the diesel had.

Martin.


Top
 Profile  
 
 Post subject:
PostPosted: Mon Feb 23, 2009 10:00 am 
Offline

Joined: Tue Jul 31, 2007 5:00 am
Posts: 91
probably not the exact same HP, because electric motors have more torque at lower RPMs than an internal cumbustion engine

_________________
I cut it, and I cut it, and it was still too short!


Top
 Profile  
 
 Post subject:
PostPosted: Mon Feb 23, 2009 12:33 pm 
Offline
User avatar

Joined: Wed Dec 24, 2003 5:19 am
Posts: 3119
Location: Nashville, Tn.
Electric motors smell better, too. :lol:

Unless of course you're using biodiesel and then your engine smells like french fries. Yumm.

_________________
Isn't it amazing!! The person that never has the fortitude to pursue his own dreams, will be the first to try and discourage you from pursuing yours.


Top
 Profile  
 
 Post subject:
PostPosted: Mon Feb 23, 2009 5:17 pm 
Offline
User avatar

Joined: Wed Nov 12, 2003 5:25 pm
Posts: 3425
Location: Coastal Georgia
HP is HP no matter how you get it.
The things that make 'different' HP is power/weight ratio, and the RPm that you produce that given HP. (and this defines torque)

Example; if you make 50hp @ 3000rpm, then it dont make a difference if you getting it with gas, diesel, electric or otherwise, as long as you are talking about 50hp @ 3000.


Top
 Profile  
 
 Post subject:
PostPosted: Mon Feb 23, 2009 8:15 pm 
Offline
User avatar

Joined: Thu Mar 01, 2007 7:33 am
Posts: 2292
Location: Owasso, Oklahoma
In the words of Homer Simpson...mmm french fries and the smell of electric motors.

_________________
Bill

I told my wife we needed a three-car garage for my projects...she told me to ask her for permission next time before I buy a house.
http://www.unitybuild.net


Top
 Profile  
 
 Post subject:
PostPosted: Tue Feb 24, 2009 6:35 am 
Offline
User avatar

Joined: Fri Dec 08, 2006 5:21 pm
Posts: 8007
Location: tarpon springs fl
check this site out....replacement for diesel & an electric outboard:

http://www.solidnav.com/index.htm

_________________
Boat building can best be defined as an endless series of
tragedies obscured by the occasional miracle, followed by a good bottle of beer.

Don't Dream Your Life, Live Your Dream


Top
 Profile  
 
 Post subject: Electric Power
PostPosted: Tue Feb 24, 2009 7:51 am 
Offline

Joined: Thu Aug 21, 2008 6:59 am
Posts: 130
Location: Chester, SC
Question:
If the power cord leaks juice, will it shock you when you mop it up? :lol:

Bob Smith
Chester, SC (Electrified in the late 1800s)

I am an expert of electricity. My father occupied the chair of applied electricity at the state prison.
W. C. Fields


Top
 Profile  
 
PostPosted: Fri Oct 23, 2009 4:01 pm 
Offline

Joined: Fri Oct 23, 2009 3:16 pm
Posts: 3
Location: California
In doing research for my own Solar Powered boat plans, I learned that the correct formula to convert gas HP to Electric HP is 2.73.
In other words one (1) Elec hp = 2.73 Gas hp. Electric motors also have a more even or consistant torque level through out the entire RPM range.


Top
 Profile  
 
PostPosted: Fri Oct 23, 2009 6:29 pm 
Offline
User avatar

Joined: Wed Aug 26, 2009 2:43 pm
Posts: 142
Location: Seattle
Ltjamesd wrote:
In doing research for my own Solar Powered boat plans, I learned that the correct formula to convert gas HP to Electric HP is 2.73.
In other words one (1) Elec hp = 2.73 Gas hp.

Huh? With all due respect, that makes no sense. One horsepower is one horsepower is 33,000 foot pounds per minute, no matter what energy source is supplying it.

_________________
Photos of my Squirt build
El Toro I built with my Dad


Top
 Profile  
 
PostPosted: Fri Oct 23, 2009 8:30 pm 
Offline
User avatar

Joined: Mon Feb 02, 2009 12:06 am
Posts: 267
Location: BC coast
Aaron, that might be an 'anecdotal' ratio based more on experience than math...though it sounds a little specific for that.
With an electric motor conversion you free up hp by not spinning the drivetrain and accessories,so the hp that the prop sees is closer to what the motor can actually produce.
At least, that's how I took it. :)

_________________
-Brian

"Do or do not. There is no try."
- Yoda


Top
 Profile  
 
PostPosted: Fri Oct 23, 2009 11:36 pm 
Offline

Joined: Fri Oct 23, 2009 3:16 pm
Posts: 3
Location: California
I'll find the exact tech specs and post it on here. I also read another post here that talks about commercial operations converting their gas 350 Merc to 150 hp Electric, meaning equal power conversion. In the mean time here are a few quotes:
"Electric motors are upwards of 90% plus efficient. Internal combustion engines are 30% to 35% at best. That is another reason for a guideline if you need or have a 30hp gas engine. A 12hp electric motor would be almost the same. 30% of an IC's energy is wasted in the heat from the exhaust. IC engines are terribly inefficient."

"From contributor T:
It is generally accepted that an electric motor will give what can be construed as horsepower at about 2 1/2 times the rate of a gas engine. It has to do with the electric motors ability to keep its rpm up with a correspondingly high amount of torque over a wide range. Electric motors start up with very high torque, level off slightly under, and maintain that level throughout."

"From contributor C:
It's true. In most all cases, a machine that requires 10 hp will require 2 to 3 times more if equipped with a gas engine."

I'm just sharing what I've read from reliable sources, like motor manufacturing companies, and it's how I'm planning my project. I'm not trying to get into a Physics lab arguement.


Top
 Profile  
 
PostPosted: Fri Oct 23, 2009 11:45 pm 
Offline

Joined: Fri Oct 23, 2009 3:16 pm
Posts: 3
Location: California
"The OSSA Powerlite system incorporate two 25kw generator (combined 67 hp) driving two 35hp propulsion motors. These replace the twin 75 or 100hp Yanmar engines that have previously used on sisterships along with a "Mini 8" Fischer Panda generator."

http://www.ossapowerlite.com/customers/ ... ast_47.htm

http://www.solomontechnologies.com/m_recreational.htm

This might be helpful. Have fun exploring.


Top
 Profile  
 
PostPosted: Sat Oct 24, 2009 9:27 am 
Offline
User avatar

Joined: Mon Feb 02, 2009 12:06 am
Posts: 267
Location: BC coast
James, as the new guy I hope you don't take any of this personally. The folks here like to kick stuff around but everyone gets along.
Thanks for the additional info and links BTW.
I'd be interested in a thread on where you're at with planning your solar project.

bob smith wrote:
chair of applied electricity

That is just too funny...

_________________
-Brian

"Do or do not. There is no try."
- Yoda


Top
 Profile  
 
PostPosted: Sat Oct 24, 2009 1:32 pm 
Offline

Joined: Thu Jan 24, 2008 11:36 am
Posts: 307
Location: Kenai, Alaska
AaronStJ, seemed to me to bring up the reason for the confusion in this topic and the seemingly conflicted sources or references. AStj used the physical constant [33k ft.lb/min=hp] and asked how were the two different types of machines changing 'physics'- isn't one HP one HP "all the world over"?

I think that what has happened here is the rating methods, and the labeling methods versus the physical constants creates an apples and oranges conversation? I don't think electric motors and reciprocating engines have universal testing standards so they don't have common ratings, and the difference is in the rating methods and numbers that follow.

First, reciprocating internal combustion engines are advertised by total [possible] hp which is [unfortunately] too often measured by cranking the engine to highest redline and the applying a brake to the running engine and measuring the heat generated to stop the engine running. That heat amount is "converted" to Hp. This isn't the Hp at the top of the torque curve, nor is it really usable Hp because you'd have to run the engine at that condition to see that horse power.

Fueled engines most often are rated with peak possible, all out, redline pushing revs, and that is more or less 'ad speak' instead of there hp at peak torque or in 'cruising' rpms. So the 100 hp diesel is really delivering 35 or 40 hp to the shaft at 'normal' operating conditions, compared to anywhere near 100 "advertised, named, and possible" hp that the advertising/marketing guys have labeled this engine.

Now electric motors are more often specified by engineering types as opposed to the advertising guys, the latter tend to exaggerate, or 'hype' as we say now, compared to the former type who by training are more conservative in their labels and terms. Electric motors are often rated by math; the mass of the rotor and shaft multiplied by the revs gives a momentum and that is often converted to foot pounds and divided by 33k as AaronStJ noted. This means the electric motor is more often rated at its 'normal operating' conditions instead of at some 'ready to explode' condition.

So if one torque producer is rated by advertising people and the other by engineers who don't care about ratings being higher than the 'other guys'- just 'workings'; the 2.5:1 ratio seems more like a difference in how we've all come to talk about these two types of torque producers - instead of any real difference in the real world, physical constant facts, or some magic of one type of power over the other.

I think the reason for the 2.5:1 ratio is the amount of exaggeration used to rate reciprocating engines. To dial out the 'adspeak'; divide the advertised horse power of an engine by 2.5 and that is 'useful' power rating. Once that's done it quickly levels the difference between motors and engines and could put us all on a common conversational footing in terms of the useful work these torque producers will provide.

cheers,

_________________
Kevin Morin


Top
 Profile  
 
PostPosted: Sat Oct 24, 2009 4:53 pm 
Offline

Joined: Sat Nov 15, 2003 10:42 pm
Posts: 2373
Location: Bedrock, Ontario
Kevin Morin wrote:
This means the electric motor is more often rated at its 'normal operating' conditions instead of at some 'ready to explode' condition.


BUT its so much fun to use them when they're on the ragged edge of exploding...lol 8) :)


Top
 Profile  
 
Display posts from previous:  Sort by  
Post new topic Reply to topic  [ 19 posts ]  Go to page 1, 2  Next

All times are UTC - 8 hours [ DST ]


Who is online

Users browsing this forum: No registered users and 2 guests


You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot post attachments in this forum

Search for:
Jump to:  
Powered by phpBB® Forum Software © phpBB Group